• Applied Biosystems Abi 3500 Series Genetic Analyzer DNA Sequencer
  • Applied Biosystems Abi 3500 Series Genetic Analyzer DNA Sequencer
  • Applied Biosystems Abi 3500 Series Genetic Analyzer DNA Sequencer
  • Applied Biosystems Abi 3500 Series Genetic Analyzer DNA Sequencer
  • Applied Biosystems Abi 3500 Series Genetic Analyzer DNA Sequencer
  • Applied Biosystems Abi 3500 Series Genetic Analyzer DNA Sequencer

Applied Biosystems Abi 3500 Series Genetic Analyzer DNA Sequencer

After-sales Service: Online
Warranty: 1 Years
Applications: Forensic Lab & Medical
Number of Fluorescent Dye: 6-Color
Capillary Length (Cm): 36cm
Number of Capillary Channels: 8
Customization:
Gold Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
3500
Laser
Solid State Laser
Transport Package
160cm *60cm *90cm
Origin
Japan
HS Code
9027202000
Production Capacity
10 Sets/Year

Product Description

Applied Biosystems Abi 3500 Series Genetic Analyzer DNA SequencerApplied Biosystems Abi 3500 Series Genetic Analyzer DNA SequencerApplied Biosystems Abi 3500 Series Genetic Analyzer DNA Sequencer
The 3500 Genetic Analyzer is an 8-capillary sequencing instrument specifically designed to support the demanding performance needs of validated and process controlled environments, while retaining the unsurpassed application versatility that life science researchers expect.


This package includes an 8-capillary instrument, 3500 Series Data Collection Software, a Dell Workstation and monitor, as well as reagent kits for system qualification and secondary analysis software. The 3500 Series Data Collection Software supports sequencing and fragment analysis, and integrates seamlessly with downstream software for secondary analysis of genetic data. This package includes such secondary software: GeneMapper™ software for fragment analysis and software for resequencing applications.

Features include:

• An 8 capillary system that can easily be upgraded to a 24-capillary system when you're ready.
• Single-line, 505 nm, solid-state, long-life laser that utilizes a standard power supply and requires no heat-removal ducting
• Powerful, integrated data collection and primary analysis software provides real-time assessment of data quality
• Radio frequency identification (RFID) technology tracks key consumables data and records administrative information
• Advanced multiplexing capabilities for DNA fragment analysis with up to six unique dyes
• Unrivaled application flexibility-one array and one polymer are used for most applications.
• Simple setup, operation and maintenance

Accurate Reliable Data Quality
The 3500 series systems significantly improves signal uniformity from instrument-to-instrument, run-to-run, and capillary-to-capillary. With a combination of intelligent hardware, powerful new algorithm and reagent combinations, these methods provide major reduction in the range of signal peak heights obtained across multiple 3500 series instruments (see figure).

Improved Sizing Precision
New thermal sub-system design gives enhanced performance in demanding fragment applications enabling improved sizing precision versus previous generations of capillary electrophoresis platforms.

Ready to Use Consumables With RFID Tags
The 3500 series introduces ready-to-use consumables with pre-packaged polymer pouches, cathode and anode buffer containers, and easy-to-install capillary arrays. Each of these consumables is integrated with RFID tags that enable viewing, tracking, and reporting of critical information about reagents and consumables including usage, lot number, part number, expiry date, and on-instrument lifetime within the 3500 Series Data Collection Software.

Easy to Use Data Collection Software
3500 Series Data Collection software breaks new ground in user-friendly navigation with an intuitive dashboard design, highly visible buttons for common operations, easy-to-read graphical displays to monitor the state of consumables and handy maintenance scheduling calendar functionality. New functionality includes simplified plate set-up and built-in primary analysis with quality control, so you can make decisions about the quality of data as it is produced on the instrument without the need to transfer output files into secondary analysis software packages.

The Applied Biosystems 3500 and 3500xL Genetic Analyzers are supplied as follows:
Capillary electrophoresis instrument
8-capillary (3500 System) or 24-capillary (3500xL System) array and polymer
DNA sequencing and/or fragment analysis reagents and consumables for system qualification
Dell™ computer workstation with flat-screen monitor
Integrated software for instrument control, data collection, quality control, and auto-analysis of sample files for base calling and fragment sizing
Technical Specification
• Capillary Length: 50 cm, 36 cm
• Current: 15 amps
• Dimensions: Electrophoresis Unit Width (Closed Door): 61 cm, Electrophoresis Unit: 122 cm (W) (open door) x 61 cm (D) x 72 cm (H)
• Duration: 1 Year Limited Warranty on Parts and Labor, Service Installation and Application Training Included
• External Computer: - Hard Drive: 2x 500GB SATA 3.0 Gb/s and 8 MB Data Burst Cache - Memory: 16 GB (2x 8GB) 1600 MHz DDR3 Non-ECC. - Processor: 4th Gen Intel Core I7 Processor - 3.1 GHz Turbo Processor - Operating System: Windows 7 SP1
• For Use With (Equipment): 3500 Genetic Analyzer
• Format: 96-well plate, 8-well strips
• Laser Features: Long-life single-line 505 nm solid-state laser excitation source., Long-life single-line 505 nm solid-state laser
• Max. Voltage: Electrophoresis Voltage - Up to 20 kV
• Number of Capillaries: 8 Capillaries Operating Environment:
• Humidity: 20%-80% (non-condensing),
• Room temp.: <2° fluctuation during runs
• Room temp: <2° fluctuation during runs
• Temperature: 15°C-30°C
• Humidity: 20-80% (non-condensing)
• Polymer: POP-4™, POP-6™, POP-7™
• Polymer Consumption: - Replace at earliest of 14 days⁄96 samples⁄12 injections (96-sample pouches), - Replace at earliest of 14 days⁄384 samples⁄60 Injections (384-sample pouches), - Replace at earliest of 14 days⁄960 samples⁄120 Injections (960-sample pouches)
• Read Length: ≥420 bp using a 36 cm capillary and POP-4™, >850 bp using a 50 cm capillary and POP-7™ polymer
• Run Time: 30 to 140 min. (varies depending on run module)
• Weight: 82 kg (approximately)
• Product Type Specs: Genetic Analyzer


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
167
Year of Establishment
2016-02-24